生产环境多用DR模式。html
分发器(dir): 192.168.133.130 linux
rs1:192.168.133.132 nginx
rs2:192.168.133.133 算法
vip(虚拟IP):192.168.133.200 vim
1.分发器编写规则脚本并执行:bash
vim /usr/local/sbin/lvs_dr.sh #添加如下内容服务器
#! /bin/bash #打开端口转发 echo 1 > /proc/sys/net/ipv4/ip_forward ipv=/usr/sbin/ipvsadm vip=192.168.133.200 rs1=192.168.133.132 rs2=192.168.133.133 #注意这里的网卡名字 ifdown ens33 ifup ens33 ifconfig ens33:2 $vip broadcast $vip netmask 255.255.255.255 up #添加网关,ens33:2是添加虚拟网卡 route add -host $vip dev ens33:2 $ipv -C $ipv -A -t $vip:80 -s rr $ipv -a -t $vip:80 -r $rs1:80 -g -w 1 $ipv -a -t $vip:80 -r $rs2:80 -g -w 1
#/bin/bash vip=192.168.133.200 #把vip绑定在lo上,是为了实现rs直接把结果返回给客户端 ifconfig lo:0 $vip broadcast $vip netmask 255.255.255.255 up route add -host $vip lo:0 #如下操做为更改arp内核参数,目的是为了让rs顺利发送mac地址给客户端 #参考文档www.cnblogs.com/lgfeng/archive/2012/10/16/2726308.html echo "1" >/proc/sys/net/ipv4/conf/lo/arp_ignore echo "2" >/proc/sys/net/ipv4/conf/lo/arp_announce echo "1" >/proc/sys/net/ipv4/conf/all/arp_ignore echo "2" >/proc/sys/net/ipv4/conf/all/arp_announce
页面访问vip来观察索引页是否有变化架构
LVS的分发器挂了,整个LVS就不工做了。可在分发器作高可用。负载均衡
完整架构须要两台服务器(角色为dir)分别安装keepalived软件,目的是实现高可用,但keepalived自己也有负载均衡的功能,因此本次实验能够只安装一台keepalived。keepalived内置了ipvsadm的功能,因此不须要再安装ipvsadm包,也不用编写和执行那个lvs_dir的脚本。oop
分发器(dir+keepalived): 192.168.133.130
rs1:192.168.133.132
rs2:192.168.133.133
vip(虚拟IP):192.168.133.200
修改keepalived配置文件并开启:
vim /etc/keepalived/keepalived.conf
vrrp_instance VI_1 { state MASTER #绑定vip的网卡为ens33 interface ens33 virtual_router_id 51 priority 100 advert_int 1 authentication { auth_type PASS auth_pass aminglinux } virtual_ipaddress { 192.168.133.200 } } virtual_server 192.168.133.200 80 { #每隔10秒查询realserver状态 delay_loop 10 #lvs 算法 lb_algo wlc #DR模式 lb_kind DR #同一IP的链接60秒内被分配到同一台realserver persistence_timeout 60 #用TCP协议检查realserver状态 protocol TCP real_server 192.168.133.132 80 { #权重 weight 100 TCP_CHECK { #10秒无响应超时 connect_timeout 10 nb_get_retry 3 delay_before_retry 3 connect_port 80 } } real_server 192.168.133.133 80 { weight 100 TCP_CHECK { connect_timeout 10 nb_get_retry 3 delay_before_retry 3 connect_port 80 } } }
systemctl start keepalived
#执行ipvsadm -C 把以前的ipvsadm规则清空掉;systemctl restart network 能够把以前的vip清空掉;rs上,依然要执行/usr/local/sbin/lvs_rs.sh脚本;
关闭任意一台rs的nginx服务,分发器上执行ipvsadm -ln 查看该rs是否有被剔除。
从新开启rs的nginx服务,分发器上执行ipvsadm -ln 查看该rs是否有恢复。