数据仓库的将来 MariaDB ColumnStore

wKiom1hgitSSapaIAAA4pG6yXEQ681.jpg

MariaDB ColumnStore

简介

Part1:写在最前mysql

MariaDB ColumnStore is the future of data warehousing. ColumnStore allows us to store more data and analyze it faster. Everyday, Pinger’s mobile applications process millions of text messages and phone calls. We also process more than 1.5 billion rows of logs per day. Analytic scalability and performance is critical to our business. MariaDB’s ColumnStore manages massive amounts of data and will scale with Pinger as we grow.ios

                             ----from mariadb.comgit


Part2:大牛如何说sql

MariaDB ColumnStore是在MariaDB 10.1基础上移植了InfiniDB4.6.2构建的大规模并行,高性能,压缩,分布式开源列式存储引擎,相似收费产品Infobright。它设计用于大数据离线分析,用来抗衡Hadoop。你可使用标准SQL语句进行查询,支持目前流行的sqlyog/navicat客户端工具链接,对业务方使用没有任何的不便,而且你不须要建立任何索引,不须要修改业务方的复杂SQL(自身就支持复杂的关联查询、聚合、存储过程和用户定义的函数),你惟一要作的就是把数据导入到ColumnStore里,就没你事了。这对一家没有Hadoop工程师的公司来讲,MariaDB ColumnStore会是一个更好的替代产品。数据库

                                                        -----from 贺春旸bootstrap


Part3:环境简介后端

192.168.1.248 HE1 um1centos

192.168.1.249 HE2 um2缓存

192.168.1.250 HE3 pm1bash

192.168.1.251 HE4 pm2

Column Store架构概述

Part1:写在最前

MariaDB ColumnStore是一种专为分布式大规模并行处理(MPP)设计的列式存储引擎。它由三个组件组成,协同工做。

wKioL1hgj5KQv_J2AAEH5C9ZRyc677.jpg




在官方给出的架构图中,咱们能够看到分为三个组件构成:UM、PM、数据存储层。


用户模块(UM):

用户模块管理和控制终端用户查询的操做,它维护每一个查询的状态,向一个或多个性能模块发出请求以代为执行SQL查询工做,最后,用户模块聚集来自各个参与的性能模块的全部查询结果,以造成返回给用户的完整的查询结果集。


性能模块(PM):

性能模块负责存储,检索和管理数据,处理对查询操做的块请求,并将其传递回用户模块以完成查询请求。性能模块将获取的数据缓存在其内存中计算。MPP是经过容许用户配置尽量多的性能模块,以实现更高的处理能力。


存储:

MariaDB ColumnStore对于存储系统极为灵活。当在内部运行时,它可使用本地存储或共享存储(例如SAN)来存储数据。在Amazon EC2环境中,它可使用临时或弹性块存储(EBS)卷。当无共享部署须要数据冗余时,它被构建为与GlusterFS和Apache Hadoop分布式文件系统(HDFS)集成。


一句话总结:用户模块(UM)将客户端发出的SQL请求进行分配,分配到后端性能模块(PM),PM进行数据查询分析,将处理的结果返回给UM,UM再把PM分析的结果进行聚合,最后返回给客户端最终的查询结果。


Column Store性能对比

Percona专业MySQL服务提供商性能测试InfiniDB比其余OLAP优点明显。

wKiom1hh2rPhlcRCAACwZUif19Q578.jpg

Column Store安装

Part1:打通互信

[root@HE1 ~]# ssh-keygen
[root@HE1 ~]# ssh-copy-id '-p 22 root@192.168.1.248'
[root@HE1 ~]# ssh-copy-id '-p 22 root@192.168.1.249'
[root@HE1 ~]# ssh-copy-id '-p 22 root@192.168.1.250'
[root@HE1 ~]# ssh-copy-id '-p 22 root@192.168.1.251'
[root@HE1 ~]# ssh HE1
[root@HE1 ~]# ssh HE2
[root@HE1 ~]# ssh HE3
[root@HE1 ~]# ssh HE4
[root@HE1 ~]# cat /etc/hosts
192.168.1.248   HE1
192.168.1.249   HE2
192.168.1.250   HE3
192.168.1.251   HE4

在HE1,HE2,HE3,HE4每台机器上执行上述命令,打通ssh互信。


Part2:关闭防火墙

[root@HE1 ~]# /etc/init.d/iptables status

iptables: Firewall is not running.

[root@HE1 ~]# chkconfig iptables off

[root@HE1 ~]# chkconfig --list | grep iptables

iptables       0:off1:off2:off3:off4:off5:off6:off


Part3:关闭文件系统访问时间和修改磁盘调度策略

[root@HE1 ~]# cat /etc/fstab 

#
# /etc/fstab
# Created by anaconda on Sat Mar  5 09:35:40 2016
#
# Accessible filesystems, by reference, are maintained under '/dev/disk'
# See man pages fstab(5), findfs(8), mount(8) and/or blkid(8) for more info
#
UUID=397d50ba-22b0-4d50-9e29-89e3b92d2d07 /                       ext4    defaults,noatime,barrier=0        1 1


[root@HE1 ~]# echo "deadline" > /sys/block/sda/queue/scheduler


Part4:关闭numa

[root@HE1 ~]# cat /etc/grub.conf
# grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes to this file
# NOTICE:  You have a /boot partition.  This means that
#          all kernel and initrd paths are relative to /boot/, eg.
#          root (hd0,0)
#          kernel /vmlinuz-version ro root=/dev/sda2
#          initrd /initrd-[generic-]version.img
#boot=/dev/sda
default=1
timeout=5
splashp_w_picpath=(hd0,0)/grub/splash.xpm.gz
hiddenmenu
title CentOS (2.6.32-573.18.1.el6.x86_64.debug)
root (hd0,0)
kernel /vmlinuz-2.6.32-573.18.1.el6.x86_64.debug ro root=UUID=397d50ba-22b0-4d50-9e29-89e3b92d2d07 rd_NO_LUKS rd_NO_LVM LANG=en_US.UTF-8 rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto  KEYBOARDTYPE=pc KEYTABLE=us rd_NO_DM rhgb quiet numa=off
initrd /initramfs-2.6.32-573.18.1.el6.x86_64.debug.img
title CentOS (2.6.32-431.el6.x86_64)
root (hd0,0)
kernel /vmlinuz-2.6.32-431.el6.x86_64 ro root=UUID=397d50ba-22b0-4d50-9e29-89e3b92d2d07 rd_NO_LUKS rd_NO_LVM LANG=en_US.UTF-8 rd_NO_MD SYSFONT=latarcyrheb-sun16 crashkernel=auto  KEYBOARDTYPE=pc KEYTABLE=us rd_NO_DM rhgb quiet numa=off
initrd /initramfs-2.6.32-431.el6.x86_64.img


Part5:安装jemalloc内存管理

[root@HE1 ~]# yum install jemalloc-*

[root@HE1 ~]# reboot

在HE1,HE2,HE3,HE4每台机器上执行上述命令


Part6:安装boost软件包

[root@HE1 ~]# yum -y install boost*

[root@HE1 ~]# yum -y groupinstall "Development Tools"

[root@HE1 ~]# yum -y install cmake

[root@HE1 ~]# tar xvf boost_1_55_0.tar.gz

[root@HE1 ~]# cd boost_1_55_0

[root@HE1 boost_1_55_0]#  ./bootstrap.sh   --with-libraries=atomic,date_time,exception,filesystem,iostreams,locale,program_options,regex,signals,system,test,thread,timer,log   --prefix=/usr

[root@HE1 boost_1_55_0]# ./b2 install


Part6:安装perl依赖包

[root@HE1 ~]#  yum -y install expect perl perl-DBI openssl zlib   perl-DBD-MySQL


Part7:安装Mariadb ColumStore

[root@HE1 ~]# tar xvf mariadb-columnstore-1.0.6-1-centos6.x86_64.bin.tar.gz -C /usr/local


Part8:配置Mariadb ColumStore

[root@HE1 ~]# /usr/local/mariadb/columnstore/bin/postConfigure

wKiom1hhrObzF4fqAAI-YJ4Ti2Q962.jpg

wKioL1hhrOejBnoEAADPRk_erpg332.jpg

wKiom1hhrOfSG0zeAACk33iEwIw378.jpg

wKioL1hhrOeiqcqnAAESHqAPqOk714.jpg

wKioL1hhrOizhEFVAAEbpNFe9m0603.jpg

wKiom1hhrOnRAiQoAAFsN_f2Uv8393.jpg

wKioL1hhrOqDYTskAADbdvWGe3E608.jpg

wKiom1hhrOqTY85yAAIMbBop1SQ664.jpg

wKioL1hhrOuRjMxRAAHEmlacZ1c694.jpg

wKiom1hhrOzSG-dMAAIZz3xdJAk228.jpg

至此,MariaDB ColumnStore安装并配置完成


Column Store单点故障测试

Part1:关闭HE2


当前HE2为primary um

mcsadmin> getSystemStatus
getsystemstatus   Mon Dec 26 15:56:47 2016
System columnstore-1
System and Module statuses
Component     Status                       Last Status Change
------------  --------------------------   ------------------------
System        BUSY_INIT                    Mon Dec 26 15:56:38 2016
Module um1    AUTO_DISABLED/DEGRADED       Mon Dec 26 15:56:40 2016
Module um2    ACTIVE                       Mon Dec 26 15:54:21 2016
Module pm1    ACTIVE                       Mon Dec 26 02:03:27 2016
Module pm2    ACTIVE                       Mon Dec 26 02:03:41 2016
Active Parent OAM Performance Module is 'pm1'
Primary Front-End MariaDB Columnstore Module is 'um2'
MariaDB Columnstore Replication Feature is enabled
[root@HE2 ~]# reboot

在当前primary um重启后,能够看到primary um已经自动切换至um1

mcsadmin> getSystemStatus
getsystemstatus   Mon Dec 26 15:58:19 2016
System columnstore-1
System and Module statuses
Component     Status                       Last Status Change
------------  --------------------------   ------------------------
System        BUSY_INIT                    Mon Dec 26 15:58:10 2016
Module um1    ACTIVE                       Mon Dec 26 15:57:17 2016
Module um2    AUTO_DISABLED/DEGRADED       Mon Dec 26 15:58:11 2016
Module pm1    ACTIVE                       Mon Dec 26 02:03:27 2016
Module pm2    ACTIVE                       Mon Dec 26 02:03:41 2016
Active Parent OAM Performance Module is 'pm1'
Primary Front-End MariaDB Columnstore Module is 'um1'
MariaDB Columnstore Replication Feature is enabled


Part2:检查状态

在原primary um (HE2)中进入数据库查看,如今已是um1的从库

[root@HE2 ~]# mcsmysql 
Welcome to the MariaDB monitor.  Commands end with ; or \g.
Your MariaDB connection id is 10
Server version: 10.1.19-MariaDB Columnstore 1.0.6-1
Copyright (c) 2000, 2016, Oracle, MariaDB Corporation Ab and others.
Type 'help;' or '\h' for help. Type '\c' to clear the current input statement.
MariaDB [(none)]> show slave status\G
*************************** 1. row ***************************
               Slave_IO_State: Waiting for master to send event
                  Master_Host: 192.168.1.248
                  Master_User: idbrep
                  Master_Port: 3306
                Connect_Retry: 60
              Master_Log_File: mysql-bin.000013
          Read_Master_Log_Pos: 1879
               Relay_Log_File: relay-bin.000002
                Relay_Log_Pos: 537
        Relay_Master_Log_File: mysql-bin.000013
             Slave_IO_Running: Yes
            Slave_SQL_Running: Yes
              Replicate_Do_DB: 
          Replicate_Ignore_DB: 
           Replicate_Do_Table: 
       Replicate_Ignore_Table: 
      Replicate_Wild_Do_Table: 
  Replicate_Wild_Ignore_Table: 
                   Last_Errno: 0
                   Last_Error: 
                 Skip_Counter: 0
          Exec_Master_Log_Pos: 1879
              Relay_Log_Space: 829
              Until_Condition: None
               Until_Log_File: 
                Until_Log_Pos: 0
           Master_SSL_Allowed: No
           Master_SSL_CA_File: 
           Master_SSL_CA_Path: 
              Master_SSL_Cert: 
            Master_SSL_Cipher: 
               Master_SSL_Key: 
        Seconds_Behind_Master: 0
Master_SSL_Verify_Server_Cert: No
                Last_IO_Errno: 0
                Last_IO_Error: 
               Last_SQL_Errno: 0
               Last_SQL_Error: 
  Replicate_Ignore_Server_Ids: 
             Master_Server_Id: 1
               Master_SSL_Crl: 
           Master_SSL_Crlpath: 
                   Using_Gtid: No
                  Gtid_IO_Pos: 
      Replicate_Do_Domain_Ids: 
  Replicate_Ignore_Domain_Ids: 
                Parallel_Mode: conservative
1 row in set (0.00 sec)
MariaDB [(none)]>


Column Store测试

Part1:主键和索引

MariaDB [helei]> create table helei_innodb(
    -> id int(10) unsigned NOT NULL AUTO_INCREMENT,
    -> c1 int(10) NOT NULL DEFAULT '0',
    -> c2 int(10) unsigned DEFAULT NULL,
    -> c5 int(10) unsigned NOT NULL DEFAULT '0',
    -> c3 timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP ON UPDATE CURRENT_TIMESTAMP,
    -> c4 varchar(200) NOT NULL DEFAULT '',
    -> PRIMARY KEY(id),
    -> KEY idx_c1(c1),
    -> KEY idx_c2(c2)
    -> )ENGINE=InnoDB ;
Query OK, 0 rows affected (0.03 sec)
MariaDB [helei]> create table helei_cs(
    -> id int(10) unsigned NOT NULL AUTO_INCREMENT,
    -> c1 int(10) NOT NULL DEFAULT '0',
    -> c2 int(10) unsigned DEFAULT NULL,
    -> c5 int(10) unsigned NOT NULL DEFAULT '0',
    -> c3 timestamp NOT NULL DEFAULT CURRENT_TIMESTAMP ON UPDATE CURRENT_TIMESTAMP,
    -> c4 varchar(200) NOT NULL DEFAULT '',
    -> PRIMARY KEY(id),
    -> KEY idx_c1(c1),
    -> KEY idx_c2(c2)
    -> )ENGINE=Columnstore;
ERROR 1069 (42000): Too many keys specified; max 0 keys allowed

这里能够看出,columnstore存储引擎不支持主键也不须要索引

MariaDB [helei]> create table helei_cs(
    -> id int(10) unsigned NOT NULL ,
    -> c1 varchar(200) NOT NULL DEFAULT ''
    -> )ENGINE=Columnstore;
Query OK, 0 rows affected (0.34 sec)
MariaDB [helei]> insert into helei_cs values(1,'1');
Query OK, 1 row affected (0.60 sec)
MariaDB [helei]> insert into helei_cs values(2,'2');
Query OK, 1 row affected (0.08 sec)
MariaDB [helei]> insert into helei_cs values(3,'3');
Query OK, 1 row affected (0.17 sec)

这里能够看出columnstore的插入速度较慢


Warning:

columnstore不支持主键、索引、timestamp、collate用法、char\varchar类型的sum/average用法。



Part2:效率测试

1G内存虚拟机MariaDB ColumnStore 2.82s,线上生产库8G的innodb_buffer_pool_size该条慢查询耗时17.894s。

wKiom1hhzZPhbgsfAAHGfuXLaEI623.jpg

wKiom1hhzZPg9wC1AAA_XFox6c4203.jpg




BUG发现

若是pm2的机器挂掉了,按照本来的想法,应该pm1能够继续工做,但没法进行查询,会报错:

ERROR 1815 (HY000): Internal error: st: 10000 TupleBPS::sendPrimitiveMessages() caught an exception: IDB-2034: At least one DBRoot required for that query is offline. 


这应该是一个BUG,由于pm是负责拉取数据到内存中进行计算的,数据本文中的实验应该都存放在um机器下。咱们来查一下如今表中的数据:

MariaDB [erp_test]> show tables;
+--------------------+
| Tables_in_erp_test |
+--------------------+
| erp_bjlikp         |
| erp_bjlips         |
| erp_likp           |
| erp_lips           |
| erp_mara           |
+--------------------+
5 rows in set (0.00 sec)
MariaDB [erp_test]> select count(*) from erp_bjlikp;
+----------+
| count(*) |
+----------+
|        0 |
+----------+
1 row in set (1.15 sec)
MariaDB [erp_test]> select count(*) from erp_bjlips;
+----------+
| count(*) |
+----------+
|        0 |
+----------+
1 row in set (1.15 sec)
MariaDB [erp_test]> select count(*) from erp_lips;
+----------+
| count(*) |
+----------+
|        0 |
+----------+
1 row in set (1.14 sec)
MariaDB [erp_test]> select count(*) from erp_mara;
+----------+
| count(*) |
+----------+
|        0 |
+----------+
1 row in set (1.15 sec)

会发现全部的表行数都变为0了

ProcessMonitor      pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
ProcessManager      pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
DBRMControllerNode  pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
ServerMonitor       pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
DBRMWorkerNode      pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
DecomSvr            pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
PrimProc            pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
WriteEngineServer   pm2       AUTO_OFFLINE      Tue Dec 27 22:23:50 2016
MariaDB [erp_test]> select count(*) from erp_lips;
+----------+
| count(*) |
+----------+
|  3147299 |
+----------+
1 row in set (0.37 sec)
MariaDB [erp_test]> select count(*) from erp_mara;
+----------+
| count(*) |
+----------+
|     4361 |
+----------+
1 row in set (0.08 sec)
MariaDB [erp_test]> select count(*) from erp_bjlips;
+----------+
| count(*) |
+----------+
|  2762244 |
+----------+
1 row in set (0.13 sec)
MariaDB [erp_test]> select count(*) from erp_bjlikp;
+----------+
| count(*) |
+----------+
|    19032 |
+----------+
1 row in set (0.09 sec)
MariaDB [erp_test]> select count(*) from erp_likp;
+----------+
| count(*) |
+----------+
|   169002 |
+----------+
1 row in set (0.08 sec)

pm2机器启动后,发现又恢复正常

这应该是软件的一个bug,应该会在1.0.7GA版本修复。

感谢贺春旸老师指点,本人在测试环境中得以验证该BUG



——总结——

你们能够用生产的复杂SQL跑一跑,来体验一下。因为笔者的水平有限,编写时间也很仓促,文中不免会出现一些错误或者不许确的地方,不妥之处恳请读者批评指正。

相关文章
相关标签/搜索