vsan故障磁盘识别及更换方法总结(最佳实践)

  1. 一切操做的前提:将机器置为维护模式
  2. 定位磁盘位置(针对HPE DL380Gen10)
    [root@vsanhost01:/opt/smartstorageadmin/ssacli/bin] ./ssacli ctrl slot=0 pd all show detail | grep -E -i "physicaldrive | Drive unique ID:" | grep -E -i "physicaldrive | *6d53"
      physicaldrive 1I:3:1
      physicaldrive 1I:3:2
      physicaldrive 1I:3:3
      physicaldrive 1I:3:4
      physicaldrive 2I:3:5
      physicaldrive 2I:3:6
      physicaldrive 2I:3:7
      physicaldrive 2I:3:8
      physicaldrive 3I:2:1
      physicaldrive 3I:2:2
      physicaldrive 3I:2:3
         Drive Unique ID: 5000C500C1DA6D53619300085000C500
      physicaldrive 3I:2:4
      physicaldrive 4I:2:5
      physicaldrive 4I:2:6
3. 第二步:在主机置为维护模式后且确认故障磁盘后,能够选择热插拔更换。
4. 将新磁盘添加到磁盘组(声明一下便可)
![](https://s1.51cto.com/images/blog/201912/17/b2dd253ad3ca27f6bc13d383694fa8fd.png?x-oss-process=image/watermark,size_16,text_QDUxQ1RP5Y2a5a6i,color_FFFFFF,t_100,g_se,x_10,y_10,shadow_90,type_ZmFuZ3poZW5naGVpdGk=)
5. 这个时候,老的故障盘状态还在。等新的加好后,能够在磁盘组里将老的删掉(最佳实践)。
能够看到,新的磁盘被声明后,这个磁盘组里有5颗磁盘。
![](https://s1.51cto.com/images/blog/201912/17/cdcfb7a958556309d4d148e2b13a0730.png?x-oss-process=image/watermark,size_16,text_QDUxQ1RP5Y2a5a6i,color_FFFFFF,t_100,g_se,x_10,y_10,shadow_90,type_ZmFuZ3poZW5naGVpdGk=)
这个时候能够定位到有问题的磁盘,直接删除,屡试不爽。
![](https://s1.51cto.com/images/blog/201912/17/767223b1dede14dfc328bae7a402201d.png?x-oss-process=image/watermark,size_16,text_QDUxQ1RP5Y2a5a6i,color_FFFFFF,t_100,g_se,x_10,y_10,shadow_90,type_ZmFuZ3poZW5naGVpdGk=)
操做完毕后,能够看到磁盘组的状态正常了。