1.ss cmd conflictcmd
进入来电转接页面以后,会触发去查询来电转接的状态,所以下了T+ECUSD=1,1,"*#21#";而在还在返回查询结果时,back键退出,又点其余设置,一样会触发对应的SS查询(如下时间点触发的是CLIR的查询,下了AT+ECUSD=1,1,"*#31#")
而因为呼叫转接的查询还未返回结果,这时候又下AT+ECUSD=1,1,"*#31#",会在modem L4返回error,cause就是SS at command conflict;
Type Index Time Local Time Module Message Comment Time Different
SYS 149908 91286 11:07:14:305 NIL [AT_I p26, s17]AT+ECUSD=1,1,"*#21#"
OTA 151435 91621 11:07:15:920 CISS_2 [MS->NW] CISS__REGISTER
SYS 151578 91731 11:07:16:520 NIL [AT_I p25, s16]AT+ECUSD=1,1,"*#31#"
PS 151583 91731 11:07:16:520 L4C_2 Warning: ss cmd conflict !!
SYS 151594 91732 11:07:16:520 NIL [AT_R p25, s16]+CME ERROR: 100
OTA 151621 91762 11:07:16:720 CISS_2 [NW->MS] CISS__RELEASE_COMPLETE
SYS 151736 91762 11:07:16:720 NIL [AT_R p26, s17]OK
简单来讲,就是在下了一个 AT command来查询SS业务状态,而还未返回结果时,又下一个SS AT command,就会致使L4返回error;modem侧行为正常;command